Reinforcing steel protective layer thickness, rebar location and rebar spacing are displayed on the same screen; rebar location center is automatically read;2.2D l-a-s-e-r positioning, real-time display of rebar location and adjacent rebar centerline;3. Multiple reminders of the ...Reinforcing steel protective layer thickness, rebar location and rebar spacing are displayed on the same screen; rebar location center is automatically read;2.2D l-a-s-e-r positioning, real-time display of rebar location and adjacent rebar centerline;3. Multiple reminders of the signal value of the display frame and indicator lamps facilitate rebar positioning and core drilling;4.
Optimization of the pattern dense rebar algorithm, effectively reducing hoop interference; Dense waveform detection, the accuracy of the number of rebar roots and protective layer thickness values is greatly improved;5. Reverse compensation, automatic calculation of complex site for repair, compensation of protective layer data deviation; Product features: Measure the thickness of the concrete protective layer Positioning of reinforcement Estimated rebar diameter Test rebar spacing, display rebar grid distribution, Detection of magnetic and electrical conductors in non-magnetic and non-conductive media. - Technical features: The thickness of reinforcement protective layer, the position of reinforcement and the spacing of reinforcement are displayed on the same screen.
Automatic interpretation of rebar position center; Two-dimensional l-a-s-e-r positioning, real-time display of rebar position and adjacent rebar center line; Display frame and indicator signal value multiple reminders, convenient rebar positioning and drilling core; The pattern dense reinforcement algorithm is optimized to reduce stirrup interference effectively. Intensive waveform detection greatly improves the accuracy of the number of rebars and the thickness of the protective layer; Reverse compensation, repair the complex site automatic calculation, compensate the protection layer data deviation;Specification: 1. rebar diameter setting range: φ6mm~φ50mm 2.
Protective layer thickness measurement (nominal) range:The first range (nominal) range: 1mm ~ 120mm - The second range (nominal) range: 5mm ~ 210mm; 3. Protective layer thickness calibration range: 0 ~ ±50 mm; 2. Measuring range of different rebar diameters:Range rebar diameter(mm):φ6~φ8----φ10~φ20----φ22 and abovev - Small range(mm):1~60----1~80----1~120wide-range(mm):5~120----5~160----5~210 3.different thickness error range:Range error range(mm):±1----±2----±4Small range(mm):1~80----81~120----/wide-range(mm):5~80----81~120----121~210 4.
Diameter estimation range: φ6mm~φ50mm 5, the maximum error of diameter estimation (mm) : ±1 mm 6, distance accuracy: ±1mm 7, scanning mode: conventional scanning, procedure scanning, grid scanning, profile scanning, fine scanning, image scanning 8, power supply: built-in large capacity lithium battery 9, operation language: Chinese and English switch 10, backlight brightness: 8 adjustable 11, theme setting: 5 kinds of theme choice 12, working temperature: -10°C ~ +50°C 13, host volume: 219mm×92mm×106mm 14. Weight: 0.6kg Standard accessories:host, charger, software CD, packing case - According to the standard: GB 50010-2010 Code for Design of Concrete Structures (2015 edition) GB 50204-2015 "Concrete structure engineering construction quality acceptance Code" GB/T50344-2019 "Technical Standard for Testing Building Structures" JGJ/T152-2019 "Technical Specification for Inspection of rebars in Concrete" DB11/T365-2016 "Electromagnetic induction method test rebar protective layer thickness and rebar diameter technical specification" GBT/50784-2013 "Technical Standard for On-site Testing of Concrete Structures"